Skip to content

FANUC robot backup: types, where to store it, how often, and what happens with batteries and mastering

A FANUC robot backup is a copy of the controller's memory on a USB drive, a memory card or a server. There are two types: the file backup, All of Above, and the image backup, which copies the full memory and restarts the controller. Patti Engineering, an authorized FANUC integrator, recommends taking one after every program change and at least monthly (July 2026).

By
José Luis Villalón
Topic
Operations and support
Reviewed
November 27, 2026
Reading time
9 minutes

A FANUC robot backup comes in two forms. The file backup, All of Above, restores through a controlled start in 2 to 6 minutes, per Haas guide TG0082 (2026); the image backup copies the controller's full memory. Patti Engineering calls for a backup after every change and at least monthly (2026), and FANUC America for yearly replacement of the arm batteries (2020). Target Robotics runs FANUC robot courses in Mexico.

Panel of a FANUC R-30iB Plus controller with mode switch and emergency stop, in front of a yellow robot
In this article
  1. What is a FANUC robot backup and what types are there?
  2. Where is it stored: UD1, UT1, memory card or network?
  3. How to take an All of Above backup, step by step
  4. How do you restore a FANUC robot backup?
  5. How often should you back up?
  6. FANUC robot batteries: which ones and when to replace them
  7. FANUC robot mastering: what it is and which method applies
  8. The cell folder: what to store apart from the robot
  9. The missing test: restore the backup

Four D-size batteries in the base of the arm and one 3 V lithium battery on the controller’s main board: that is how a FANUC M-410iB/140H, a palletizing robot, with an R-30iB controller remembers what it knows. The first set keeps the position of each axis (manual B-83164EN/04, March 2017) and the second keeps the memory that holds programs and system variables (R-30iB controller manual, B-83195EN/08, February 2016). A FANUC robot backup is the copy of that memory on a medium kept outside the cabinet.

The controller manual asks for it routinely: when the main board or the FROM/SRAM memory module is replaced, its contents are lost, and with an active alarm the backup may be disabled.

What is a FANUC robot backup and what types are there?

FANUC America distinguishes the file backup from the image backup: its tutorial on updating CRX software shows how to take both before starting (Tech Transfer, August 14, 2023). From the teach pendant, the handheld programming unit, single files can be loaded too.

TypeWhat it savesWhat it does on restoreDoes it stop production?
Files, All of Above (AOA)What you see from the teach pendant: TP and KAREL programs, system variables, frames, mastering, inputs and outputs (drag&bot)Returns programs and settings to a controller that powers up (Haas, 2026)Taking it, no restart in the Haas steps; loading it needs a controlled start
ImageFull copy of FROM and SRAM memory, with the core software and its options (drag&bot)Recovers the robot after a main board or FROM/SRAM module replacement (drag&bot); it loads through the Boot Monitor (Patti Engineering, 2026)Yes: the controller restarts
Single filesTP programs, registers, framesClones or corrects one part: FANUC America copies 6 files from one robot to another, with registers, frames and TP programs (Nov 6, 2026); the system files, which carry the mastering, stay on each robotDepends on the file

drag&bot, a robot software developer, and Patti Engineering, an authorized FANUC integrator, describe the image as the full state of the controller (both checked November 27, 2026).

To take the image, the controller restarts, and drag&bot cites 4 to 5 minutes for the process. Take both: All of Above to read and load files, and the image to bring back a controller that lost its memory.

Where is it stored: UD1, UT1, memory card or network?

UD1 and UT1 are two USB ports on the same robot. The Haas TG0082 guide, whose robot package uses FANUC robots, names them this way: UD1 is the port on the controller door and UT1 is the one on the teach pendant (revision E, January 2026). Patti Engineering refers to a standard FAT32 USB drive, and drag&bot recommends 2 GB at most.

The manuals also mention the memory card, which the R-30iB manual draws as a PCMCIA card. For plants with 10 or more robots, Patti Engineering describes network backup, over FTP to a server.

Two plain practices:

  • One folder per backup. Patti Engineering suggests naming it with robot, controller, software version and date; add the serial number.
  • Two copies, one outside the cell. Patti Engineering calls for a copy off site or in the cloud.

How to take an All of Above backup, step by step

Haas publishes these steps in guide TG0082, where it is called an MD backup. Menus change with the controller and the software version, and the work belongs to trained personnel. Follow your controller manual and your plant’s lockout procedure.

  1. Plug the USB drive into UD1 or UT1.
  2. Press MENU and open File; with F1 [TYPE], choose File.
  3. With F5 [UTIL], open Set Device and choose the port that holds the drive.
  4. Press F4 [BACKUP]. If it is missing, press FCTN and choose RESTORE/BACKUP.
  5. Choose All of above and confirm with F4 [YES].

A backup with only TP programs leaves out system variables, mastering and inputs and outputs: that is the gap Patti Engineering describes.

How do you restore a FANUC robot backup?

Loading an All of Above stops the robot: the Haas guide starts with a controlled start. Two conditions come before a restore:

  • Back up the current state. Haas makes it a warning: without a prior MD backup, the robot will have to be recovered (TG0082, revision E, January 2026).
  • Load only a backup of the same robot, with its F number, taken after the last mastering. All of Above includes the system files, with the mastering data (drag&bot), and overwrites the current ones. With a backup from another robot, or an earlier one, single files are loaded without the system files, with service support. This is the article’s recommendation.

With that in place, the Haas steps:

  1. With the USB drive plugged in, power up the controller while holding PREV and NEXT until the configuration menu appears.
  2. Type 3 and ENTER: controlled start.
  3. Under MENU, File, use F5 [UTIL] and Set Device to choose UD1: or UT1:.
  4. Open the backup folder until its files are listed.
  5. Press F4 [RESTOR], choose All of above and confirm the overwrite with F4 [YES].
  6. When it finishes, FCTN and START (COLD): cold start.

Haas publishes 30 to 60 seconds of device access and 2 to 6 minutes of restore time, and asks you to reapply the DCS safety zone. The controller manual adds that SRVO-038 may appear after loading a backup, and that the remedy is mastering. After a restore, run the program at low speed and check positions before production, as Patti Engineering asks.

How often should you back up?

FANUC manuals ask for periodic backups, with no interval stated (B-83164EN/04; B-83195EN/08). The written frequency we found comes from Patti Engineering (July 15, 2026, updated September 30): after any program change, before controller maintenance or a software update, monthly at minimum on stable lines and right after commissioning.

In a palletizing cell, add every recipe change, the before and after of replacing batteries or boards, and the baseline copy when the cell is received. Patti Engineering estimates under ten minutes by USB. Back up after every change and, at a minimum, once a month.

FANUC robot batteries: which ones and when to replace them

BatteryWhat it keepsHow often, per the sourceIf it runs out
Arm: 4 batteries, standard size C or D cells depending on the modelThe encoder count, which gives the position of each axisOnce a year on a robot in use (FANUC America, 2020; Haas); in storage, inspection every 7 months (Haas)SRVO-062 BZAL: position is lost and the robot must be mastered
Controller: one 3 V lithium battery on the main boardSRAM memory, with programs and system variablesEvery 4 years (Haas; B-83195EN/08)SYST-035 warns; if voltage keeps dropping, the memory contents are lost

The arm batteries are replaced with the controller powered on and the emergency stop pressed, to keep the position of the axes (B-83164EN/04; Haas, October 13, 2021). The first interval runs from the date of manufacture (Haas, checked November 27, 2026). Hour-based intervals and their adjustment for 3 shifts are in FANUC robot preventive maintenance.

Before SRVO-062 there is a warning, SRVO-065 BLAL: the manual asks for new batteries immediately, with the controller powered on. For the controller battery, FANUC allows one to two weeks once SYST-035 appears, and the procedure is different: back up, turn the controller on for about 30 seconds, turn it off and replace the battery within 30 minutes, because the memory is lost if the battery stays disconnected for a long time (B-83195EN/08, February 2016). The arm batteries are replaced with the controller powered on; the controller battery, with the power off and within 30 minutes, with the backup already taken. The other codes are in FANUC robot alarm codes.

FANUC robot mastering: what it is and which method applies

Mastering associates the angle of each axis with the pulse count of its absolute encoder. The robot leaves the factory mastered; it has to be repeated after replacing a motor, an encoder, a reducer, the wrist or a cable, and when the arm batteries run out (B-83164EN/04, 2017).

FANUC America explains two recovery methods (November 18, 2026):

  • Zero Position Master. Each axis is jogged with the teach pendant until its witness marks line up; the manual warns that it relies on a visual check and may lack accuracy.
  • Quick Master. It uses a reference position stored beforehand. It is valid when the pulse count was lost to low battery voltage; it stops being valid after an encoder replacement or mechanical disassembly (FANUC America, September 12, 2025), and when the controller lost its mastering data (B-83164EN/04).

Mastering data lives in the controller, in the variable $DMR_GRP.$MASTER_COUN, and travels in the system files of the backup (drag&bot); Haas publishes how to load a single one, SYSMAST.SV, under a controlled start. If the controller memory was lost and the encoder keeps its count, the manual allows entering that data by hand, and asks you to record it on the data sheet every time the robot is mastered. With dead batteries, loading the backup leaves the encoder count pending: replace them, reset the alarm and master the robot.

FANUC warns that incorrect mastering can make the robot move unexpectedly (B-83164EN/04). Record the mastering data and mark the reference position while the robot is healthy. The FANUC Mexico electrical maintenance course covers backup, restore and mastering (checked November 27, 2026); how to compare syllabi is in FANUC training cost in Mexico.

The cell folder: what to store apart from the robot

The backup covers the robot controller, and the cell has more equipment with its own memory. This list is the article’s recommendation:

  • PLC program, with version and date.
  • Project and recipes of the operator interface (HMI).
  • Drive parameters for the conveyors.
  • Up-to-date electrical and pneumatic drawings.
  • Spare parts list with part numbers, batteries included.
  • Mastering data sheet and photos of the witness marks.
  • The data the cell was designed for, which fits on the line data sheet.
  • The latest All of Above and the latest image, with date and serial number.

If the cell uses vision, FANUC America notes that the backup leaves out camera images (January 21, 2026). If the robot is second-hand, ask for this folder with the machine and read what to check on a used robotic palletizer. If you have a maintenance and support contract, put in writing who takes the backup and where each copy is kept.

The missing test: restore the backup

Patti Engineering warns that a copy that was interrupted, or stored on a failing drive, may be incomplete, and suggests testing a restore in ROBOGUIDE, FANUC’s simulator, from time to time. FANUC America does exactly that in its November 6, 2026 tutorial, with 6 files and two virtual robots running side by side.

The other route is a planned stop: restore on the robot through a controlled start, under the two conditions above, and check positions at low speed. Pick one of the two and put a date on the maintenance calendar.

Target Academy, by Target Robotics, has 7 FANUC robot courses. Before you enroll your technician, ask in which one backup, restore and mastering are practiced.

Frequently asked questions

We have never backed up the robot. Where do we start?
The most direct FANUC robot backup is the file backup, All of Above: a USB drive in the teach pendant port (UT1) or the controller door port (UD1), then the File menu, BACKUP and All of above. Haas describes it in its TG0082 guide (2026) and says it takes a few minutes. Trained personnel do it, with your controller manual at hand.
SRVO-062 BZAL came up. Does loading the backup fix it?
A backup alone leaves it in place. That alarm means the encoder ran out of battery power and lost its count. The FANUC M-410iB/140H manual (2017) calls for replacing the batteries, resetting the encoder alarm and mastering; quick mastering works as long as the mastering data is still in the controller. The backup recovers that data when the controller memory was lost.
Does an image backup stop production?
Yes. The controller restarts to take an image: drag&bot describes 4 to 5 minutes for the process (checked November 27, 2026). Schedule it during a planned stop. The Haas steps for the file backup run from the File menu, with no restart.
Which USB drive works, and which port do I use?
Patti Engineering refers to a standard FAT32 USB drive (2026), and drag&bot recommends 2 GB at most because the controller reads the whole drive. Haas names two ports: UD1, on the controller door, and UT1, on the teach pendant. In Set Device, pick the same port where you plugged in the drive.
The batteries were changed with the robot powered off. What now?
If the controller was off while the arm had no batteries, the robot loses its axis positions and must be mastered again (FANUC manual B-83164EN/04, 2017; Haas, 2021). Trained personnel do it: FANUC warns that incorrect mastering can cause unexpected motion. Have the mastering data sheet and the latest backup at hand.

Sources

  1. Haas, robot package troubleshooting guide, TG0082, revision E, Jan 2026 (in Spanish)
  2. Haas, how to restore the ROBOT_ACTIVATION and SYSMAST.SV files, undated, checked Nov 27, 2026
  3. FANUC America, Tech Transfer, FANUC Backup and Restore Files, Nov 6, 2026
  4. FANUC America, Tech Transfer, CRX Controller Software Update, Aug 14, 2023
  5. FANUC America, Tech Transfer, viewing iRVision camera data from a backup, Jan 21, 2026
  6. FANUC, R-30iB controller maintenance manual, B-83195EN/08, Feb 2016, public copy hosted by PDFCOFFEE
  7. FANUC, M-410iB/140H mechanical unit manual, B-83164EN/04, Mar 2017, public copy hosted by Dentech
  8. drag&bot, FANUC R-30iB controller backup and restore, checked Nov 27, 2026
  9. Patti Engineering, Backing Up FANUC Robot Programs, Jul 15, 2026, updated Sep 30, 2026
  10. Haas, robot package maintenance schedule, checked Nov 27, 2026 (in Spanish)
  11. Haas, robot arm battery replacement, Oct 13, 2021 (in Spanish)
  12. FANUC America, Tech Transfer, FANUC Changing Batteries, Dec 3, 2020
  13. FANUC America, Tech Transfer, FANUC Multiple Mastering Methods, Nov 18, 2026
  14. FANUC America, Tech Transfer, Quick Mastering on R-30iB Plus Using Power Off Position, Sep 12, 2025
  15. FANUC Mexico, electrical maintenance course on the R-30iB Plus controller, checked Nov 27, 2026 (in Spanish)
Portrait of José Luis Villalón

José Luis Villalón

CEO of Target Robotics. Electronics engineer from the Instituto Tecnológico de Morelia. He trained at the FANUC training center in Rochester Hills, Michigan, and founded Target Robotics in San Luis Potosí in 2001, with two engineers.

With 6 facts about your line, we reply by email with the version that fits and what is needed for a quote.

  1. 1What you palletize
  2. 2At what speed
  3. 3How many lines
  4. 4Your pallet
  5. 5How many shifts
  6. 6Space and city